“So easy, a dog can do it!”
How to perform an accurate HVAC load calculation
Energy Marketing Service (EMS) has been providing professional HVAC load calculation software for contractors, engineers, HVAC professionals, and DIY’s since 1986. The owner and developer is John R. White, Author of “Guide to Passing the HVAC Exam” and “Guide to Passing the Plumbing Exam”. Our software sizes residential and commercial systems accurately using procedures prescribed by ACCA Manual J, Manual S, and Manual D and ASHRAE’s “Handbook of Fundamentals
Why the EMS load calculator.
Before discussing why the EMS load calculator is an excellent choice for sizing hvac equipment, lets first, discuss, “Why even perform a load calculation”? In the “old days”, before air conditioning, people just guessed at the furnace size. After a while, a rule of thumb began to emerge; say, 40 btuh per square foot. To this day, many contractors still use this method for sizing. If the furnace is grossly oversized, it will short cycle, continuously cut on and off, while wasting fuel and shortening its life, like a car continuously driven in stop and go traffic. Also, short blasts of hot air will leave hot and cold areas in the house. A furnace needs to run about 15 minutes before reaching its peak efficiency. The ideal solution for comfort and economy is to size the furnace so that it runs as long as possible during the on cycle. A load calculation will determine the precise btuh capacity needed to reduce short cycling to a minimum, which, increases comfort and economy.
Ok, now let’s talk about air conditioning. AC is more complicated than heating. Air conditioners change the properties of the conditioned air. If the AC unit is not sized correctly the relative humidity may rise to a level that is detrimental to the structure and/or your health. When cooling the air, humidity must be controlled.
Think of humidity as water vapor in the air. You may have been told warm air holds more moisture than cold air. Well, you were correctly told. If we were to take a bucket of air and cool it down, sooner or later, it will not be able to contain what moisture it started with. The excess moisture will condense to a pool onto the floor of the bucket. The temperature at which we see condensation is called the dew point temperature.
Although, you cannot see the vapor, it is in the air as tiny specs called grains. If we fill a bucket with 75F air and somehow count the grains of moisture as 100. We can say the absolute humidity is 100 grains. If the air is at a temperature that allows it to hold 200 grains before becoming saturated, then the humidity is now 50% relative humidity. It is called relative humidity because the actual amount of moisture present is 50% of what it could hold when the air is saturated. Relative humidity is the grains of moisture relative to the grains required to saturate the air (100/200=.50)
Fortunately, an air conditioner cools and dehumidifies at the same time. As the warm moist air passes though the cooling coil, the moisture condenses, and falls into the drain pan where it is routed to the outdoors. When the AC is running, it simultaneously cools and dehumidifies at the same time. In hot and humid areas, an oversized AC unit will do a fine job cooling the space; the problem is, an oversized ac will not run long enough to lower the RH. In addition, the short cycling does not allow the cooling coil to completely drain, allowing the fan to blow moist air back into the conditioned space as it ramps back up.
To answer the original question; Why perform an EMS load calculation? The answer is, to provide optimal comfort, economy, a healthy environment and protect the structure.
Comfort- A properly sized AC unit will run longer, thus distribute the air more evenly.
Economy- Its been estimated a savings of 5% -7% on operating cost is realized for each degree the thermostat is turned up. The human body feels about the same level comfort at 78F @ 50% RH or 74F @ 70% RH. A properly sized AC unit could save 20% or better on the AC bill simply by lowering the RH.
A properly sized AC unit operates at highway miles , not stop and go traffic.
Health- We’re not going to go into the effects of mold and high humidity on health. Mold likes to grow in places that sport an RH of 60% or higher. A properly sized AC unit attempts to maintain 55% or less RH. Although you may not be able to see it, moisture tends to form on the surface of sheetrock, paneling and porous items in unconditioned areas, such as closets and closed off rooms.
ACCA’s Manual J is the industry standard for hvac load calculating. In the 1960’s Manual J was the first attempt to standardize a method of sizing hvac equipment. The methodology and physical data used was referenced by ASHRAE’s (American Society of Heating, Refrigeration and Air Conditioning Engineers) “Handbook of Fundamentals”. The original Manual J was about 60 pages. A trained person could perform a load calculation on a napkin in ten minutes. In 1986 Manual J was revised to its 7th edition, 126 pages, as it added more and more elements effecting the load. In 2016, ACCA introduced its 8th edition, 627 pages. Admittedly, it is much more accurate than the 7th edition. However, after carefully performing residential load calculations using the 8th edition, the results are so similar that, in most cases, it just doesn’t warrant the effort required to wade through the endless charts and tables added to the 8th edition. At the end of 1980’s WrightSoft developed its software, computerizing the 7th edition. RHVAC followed shortly afterward with its version of Manual J. Today, performance of load calculations acording to the 8th edition are mostly done with computer software.
Having the position as the founder and manager of the Energy Conservation Dept. of an electric utility. I have performed 1000’s of load calculations; most were performed prior to computerization. Having worked with 100’s of hvac contractors, I asked, “Why don’t you perform load calculations on every job”? The most common answers were, “Because the software is too expensive, too cumbersome and takes too much time to perform.” The EMS load calculator was then born. I produced a program that is just as accurate as anything on the market that cost less, is very easy to learn and eliminates the fat the other software developers insist on loading into their programs.
Hi folks,
Welcome to my site. Please feel free to contact me with any questions, comments or for assistance with our load calculation software
John White
Email: energymarketingservice@gmail.com
Phone: 252-943-1028
100% Money Back Guarantee
If, for any reason, you are not happy with our software within 60 days of your purchase, simply send me an email or call’ stating you want a refund. You will receive an immediate 100% refund. Try getting a refund from other software developers
What the EMS hvac load calculator offers:
- Sizes air conditioners, furnaces, boilers and heat pumps, or mini splits
- Performs both residential and commercial calculations for one low price
- Sizes ductwork according to manual D
- Performs room-by-room calculations for sizing electric baseboard, hydronic convectors
- Contains Equipment selection tools based on Manual S; Matches equipment to the sensible and latent loads, Selects proper fan speed for humidity control.
- Sells jobs for you; Performs cost analysis- calculates ROI, pay back, based on fuel type, SEER, AFUE and HSPF
- Povides a printed report for submittals and permitting
- Real live support is just a phone call or email away
Order now and start using this software in the next few minutes
As soon as your payment has been varified, you will receive instructions, on your computer screen, to create a unique username and password along with information to access the softw
100% SATISFACTION GUARANTEE
Purchase permanent Residential and Commercial program
Only $199
Your payment will be safely processed by Paypal.
All other cards accepted
Includes both residential and commercial load calculators, plus duct sizing, equipment selection and cost analysis software for one low price. This software never expires and includes free updates.
Or
60 Day Trial
For a one time or DIY project, we offer a $49 sixty-day residential calculator. This is the same software as our perminent version above. Allows for an unlimited number of projects. However, it expires after 60 days.
Our 100% satisfaction, money back guarantee also applies
60 day trial only $49
All cards accepted
ENERGY MARKETING SERVICE
353 Winfield Lane, Pinetown, NC 27865
252-943-1028
FREE TOOLS (works with Google Sheets)
Check your AC efficiency and capacity
Size your duct system according to manual D
Estimate and compare operating cost of proposed hvac systems